369-HI-0-M-F-E-0 GE Module Parts Motor Management Relay new
The GE Multilin 369-HI-0-M-F-E-0 is a digital motor management relay designed to protect, monitor, and manage medium-sized AC motors in industrial power systems. Part of the GE Multilin 369 Motor Management Relay series, it combines motor protection functions, electrical monitoring, fault diagnostics, and communication capabilities in a single device.
The relay continuously monitors motor operating conditions and evaluates them against configured protection settings. Depending on the selected options and application configuration, it can help detect thermal overload, phase-current imbalance, undercurrent, and other abnormal operating conditions before they cause serious equipment damage.
This model includes the high-range control-power option, metering functionality, a fiber-optic interface option, and enhanced diagnostic-related features as indicated by the ordering code. The complete installed option set should be verified against the unit's nameplate and configuration.
The GE Multilin 369-HI-0-M-F-E-0 is suitable for industrial motor protection applications where reliable equipment monitoring, fault analysis, and coordinated protective control are required.
| Parameter | Specification |
|---|---|
| Brand | GE / GE Multilin |
| Product Series | Multilin 369 |
| Model Number | 369-HI-0-M-F-E-0 |
| Product Type | Digital Motor Management Relay |
| Primary Function | AC motor protection, monitoring, and control |
| Control Power Option | HI – high-range control power |
| High-Range Control Power | 50–300 V DC / 60–265 V AC, subject to the applicable manual revision |
| RTD Option | 0 indicates no built-in optional 12-RTD package in the ordering code |
| Metering Option | M – metering package |
| Fiber-Optic Option | F – fiber-optic port |
| Communication Option | Verify the complete order code and installed interface |
| Phase Current Inputs | Supports 1 A and 5 A CT secondary inputs |
| Protection Functions | Configurable motor protection functions, depending on the installed options |
| Monitoring | Motor current and other supported electrical and operating values |
| Diagnostics | Event records and supported fault-analysis functions |
| Configuration Software | GE Multilin EnerVista 369 Setup |
| Typical Application | Medium-sized AC motor protection |
| Installation | Electrical protection and motor-control panel |
| Product Status | Legacy product; confirm current availability |
Before installing or replacing the GE Multilin 369, qualified electrical personnel should follow the applicable manufacturer documentation and site safety procedures.
- Verify the complete model code: Confirm
369-HI-0-M-F-E-0against the existing relay nameplate and equipment bill of materials. - Check the control-power supply: Ensure that the supply matches the relay's HI control-power rating.
- Verify CT connections: Confirm the current-transformer secondary rating, polarity, and wiring before energizing the relay.
- Review motor settings: Enter the correct motor full-load current, starting characteristics, thermal limits, and other application-specific parameters.
- Configure metering and communications: Confirm which interfaces are installed and configure them according to the control-system requirements.
- Validate protection coordination: Check pickup levels, time delays, and trip logic against the approved protection study.
- Perform functional tests: Test protection elements, alarm contacts, trip outputs, and communication using approved commissioning procedures.
- Review diagnostics: Confirm that status indications and event records are available and that no unresolved faults remain.
It is a digital motor management relay in the GE Multilin 369 series, designed to protect and monitor medium-sized AC motors.
The HI option identifies the high-range control-power version. The applicable manual specifies 50–300 V DC or 60–265 V AC for this control-power option. Always check the relay nameplate before connecting a supply.
The M field in the ordering code indicates the metering option. Available measurements and output functions should be confirmed against the product documentation for the exact unit.
The F field identifies the fiber-optic port option in the GE Multilin 369 ordering system. Verify the exact port and connection requirements before integrating it into an existing system.
GE Motor Management Relay
,369-HI-0-M-F-E-0 Relay Module
,GE Module Parts Relay
-
IC695CPE305 GE Module Parts PACSystems RX3i Central Processing Unit
GE IC695CPE305 PACSystems RX3i CPU features a 1.1 GHz Intel Atom processor, 5 MB user memory, and battery-less retention. Offers Ethernet and isolated RS-232, wide temperature range, and 1-year warranty. USA-made, plug-and-play, with custom options available. -
IS220PDIH1BD GE Module Parts Packaged Discrete Input I/O Pack
GE IS220PDIH1BD offers 24 optically isolated input channels, dual redundant Ethernet, and hot-swap support for Mark VIe turbine control. Rugged, certified (CE, UL, ATEX), with 1-year warranty and USA origin. -
V7768-31200 GE Module Parts VME Single Board Computer
GE V7768-31200 VME single-board computer delivers high-performance Intel Core 2 Duo processing for industrial control and real-time computing. Features dual Gigabit Ethernet, 2GB DDR2, PMC expansion, and VMEbus support. Backed by a 1-year manufacturer warranty.