IS215VPROH2B GE Module Parts Turbine Emergency Trip Protection Base Board

Product Summary
The GE IS215VPROH2B is a high-integrity turbine emergency trip protection base board for Mark VI systems. It offers independent overspeed detection, fast deterministic trip response, and supports simplex or TMR redundancy. Features include IONet communication, front-panel diagnostics, and compatibility with TPRO/TREG boards. Ideal for power generation safety loops, with a 12-month warranty.
Product Description
Product Overview

The GE IS215VPROH2B is the base VPRO turbine emergency protection assembly board for the GE Mark VI Speedtronic turbine control system. It serves as an independent high-integrity safety protection module for emergency overspeed detection, turbine trip logic, and safety shutdown execution.

This base board is the foundation variant for the IS215VPROH2BC and IS215VPROH2BD versions. It accepts magnetic pickup speed signals, thermocouple inputs, 4-20mA analog signals, and discrete trip contact inputs, and drives trip relay outputs to TPRO and TREG terminal boards.

Equipped with a dedicated independent protection processor, it delivers fast deterministic trip response separate from the main control processor, supporting simplex and Triple Modular Redundancy (TMR) configurations for power generation safety loops. It features front-panel diagnostic LEDs and an IONet communication interface.

GE IS215VPROH2B VPRO turbine emergency trip protection base board for Mark VI Speedtronic control system
GE IS215VPROH2B VPRO Turbine Emergency Trip Protection Base Board
Product Parameters & Specifications
BrandGeneral Electric (GE)
ManufacturerGE Vernova
Part NumberIS215VPROH2B
Functional AcronymVPRO (Turbine Protection)
SeriesMark VI Speedtronic Turbine Control System
Module TypeTurbine Emergency Trip Protection Base Board
Redundancy SupportSimplex and Triple Modular Redundancy (TMR)
Input SignalsMagnetic pickup speed signals, thermocouple inputs, 4-20mA analog inputs, discrete trip contact signals
Output SignalsTrip relay outputs for shutdown solenoids and trip circuits
CommunicationIONet Ethernet interface
Internal Processing Frame Rate100 Hz
MPU Input SensitivityMinimum 27 mV peak at 2 Hz
Pulse Input Range2 Hz to 20 kHz
Power Supply125 VDC nominal, operating range 70–140 VDC
PCB ProtectionBase uncoated board (BC = standard conformal coated, BD = heavy conformal coated)
Operating Temperature0 °C ~ +60 °C
Storage Temperature-40 °C ~ +85 °C
Humidity10–95% non-condensing
Diagnostic IndicatorsFront-panel LED status indicators (RUN, FAIL, STATUS)
Compatible Terminal BoardsTPRO, TREG terminal boards
MountingStandard Mark VI VME rack slot installation
CoolingNatural convection
Country of OriginUnited States
Technical Specifications
  • Protection Functions: Emergency Overspeed (EOS), turbine emergency trip, synchronization check, fault interlock protection
  • Processing Mode: Independent high-speed protection processor, isolated from main control logic
  • Trip Response: Fast deterministic response for safety protection loops
  • Signal Isolation: Galvanic isolation between field sensors and internal logic circuits
  • Diagnostics: Continuous onboard self-testing and fault indication
  • Form Factor: VME rack plug-in board
  • System Architecture: Independent protection subsystem, decoupled from routine control functions
  • Solenoid Drive: Supports trip solenoid driving for turbine shutdown circuits
  • System Compatibility: Works with Mark VI Speedtronic gas and steam turbine control cabinets
  • Variant Note: This base board can be supplied as BC (standard coating) or BD (heavy coating) for different environmental requirements
Typical Applications
  • Gas turbine safety protection and emergency trip systems
  • Steam turbine overspeed protection and safety interlock control
  • Combined cycle power plant Mark VI control cabinet redundant protection subsystems
  • Turbine-driven equipment safety monitoring in the oil & gas industry
  • Power plant maintenance, spare replacement, and system retrofit projects
  • High-reliability TMR safety protection cabinets for critical rotating machinery
  • Generator protection and emergency shutdown control systems
Product Uses
  • Monitor turbine rotational speed via magnetic pickups and trigger emergency overspeed trip
  • Process thermocouple temperature signals and analog process parameters for protection interlocks
  • Execute hardwired turbine trip logic and output relay commands to trip solenoids and shutoff devices
  • Provide independent safety protection, separated from the main turbine control function
  • Support simplex and TMR redundant protection architectures for high safety integrity
  • Serve as base board for BC / BD coated variants and direct drop-in replacement for existing Mark VI VPRO racks
  • Support turbine control system overhaul, life extension, and spare inventory management
Warranty

We provide a 12-month limited warranty for the GE IS215VPROH2B board. The warranty covers functional failures caused by manufacturing defects under normal installation and operating conditions. During the warranty period, qualified faulty units are eligible for free repair or replacement. Every board is fully tested and inspected before shipment.

The warranty does not cover damage caused by improper installation, overvoltage, short circuit, physical impact, corrosion, unauthorized modification, ESD damage, or abnormal industrial misuse. Technical support is available for product consultation, wiring guidance, and fault diagnosis.

Frequently Asked Questions (FAQ)
Q1: Which control system is the IS215VPROH2B compatible with?

It is designed for the GE Mark VI Speedtronic turbine control system and works as an independent turbine protection subsystem.

Q2: What does VPRO stand for?

VPRO is the functional abbreviation for turbine protection board, dedicated to overspeed and emergency trip protection.

Q3: What is the relationship between IS215VPROH2B, IS215VPROH2BC, and IS215VPROH2BD?

IS215VPROH2B is the base board; IS215VPROH2BC is the standard conformal coated version; IS215VPROH2BD is the heavy conformal coated version for corrosive, high-humidity environments.

Q4: Does this board support TMR redundant configuration?

Yes, it supports both simplex and Triple Modular Redundancy (TMR) architectures for high safety integrity.

Q5: What power supply does this board require?

Nominal 125 VDC, with an operating range of 70–140 VDC.

Q6: What signals can this board receive?

Magnetic pickup speed signals, thermocouple inputs, 4-20mA analog inputs, and discrete trip contact signals.

Related Products
Product Details
Highlight:

GE Turbine Emergency Trip Module

,

IS215VPROH2B Protection Base Board

,

GE Module Parts Turbine Protection

Operatingtemperature: -20°C To 70°C
Temperaturerange: -20°C To 85°C
Compatibility: GE Module Systems
Powerrating: 50W
Application: Industrial Automation And Control Systems
Connectortype: Screw Terminal / Plug-in
Operatingtemperaturerange: -20°C To 85°C
Producttype: Module Parts

Miss. Liliya

Related Products
Send An Inquiry