IS215VCMIH2C GE Module Parts VME 6U Bus Master Communication Base Board

Product Summary
GE IS215VCMIH2C VME 6U Bus Master Communication Board for Mark VI turbine control. Features TI DSP, 3 IONet ports, TMR redundancy support, and plug-and-play installation. Fully tested with 12-month warranty and technical support.
Product Description
Product Overview

The GE IS215VCMIH2C is a VME 6U Bus Master Communication Base Board engineered for the Mark VI Speedtronic turbine control system. As the VME Communication Master Interface (VCMI), it serves as the central communication coordinator within Mark VI control racks, managing data exchange between the CPU and all local I/O boards while supporting both simplex and Triple Modular Redundancy (TMR) architectures.

Product Parameters & Specifications
BrandGeneral Electric (GE)
ManufacturerGE Vernova
Part NumberIS215VCMIH2C
Functional AcronymVCMI (VME Communication Master Interface)
SeriesMark VI Speedtronic Turbine Control System
Module TypeVME 6U Bus Master Communication Base Board
ProcessorTI TMS320C32 32-bit floating-point DSP
Dual-Port Memory32 KB
IONet Ports3 × 10Base2 Ethernet ports (R, S, T channels)
Diagnostic PortRS-232 serial port
Backplane InterfaceVME 6U bus
Redundancy SupportSimplex and Triple Modular Redundancy (TMR)
PCB ProtectionBase uncoated board (CA = standard conformal coated, CB = alternate coated revision)
Power Supply28 VDC nominal, operating range 18–32 VDC
Operating Temperature0 °C ~ +60 °C
Storage Temperature-40 °C ~ +85 °C
Humidity10–95% non-condensing
Diagnostic IndicatorsRUN, FAIL, STATUS, TX/RX LED indicators, reset button
MountingStandard Mark VI VME rack slot installation, normally installed in slot 1
Country of OriginUnited States
Technical Specifications
  • Bus Function: VME bus master control and backplane communication arbitration
  • Network Protocol: GE proprietary IONet / UDH protocol for deterministic turbine control
  • Data Synchronization: Low-latency real-time data exchange for turbine control loops
  • Diagnostics: Continuous self-testing, network status monitoring and fault reporting
  • Signal Isolation: Isolated communication ports to suppress industrial electromagnetic interference
  • Form Factor: 6U VME plug-in board
  • System Role: Mandatory communication coordinator for Mark VI control racks
  • Serial Function: Local configuration, firmware download and troubleshooting via RS-232
  • System Architecture: Supports multi-rack distributed I/O and TMR redundant control cabinets
  • Variant Note: IS215VCMIH2C is the base board; IS215VCMIH2CA and IS215VCMIH2CB are coated derivative versions
Typical Applications
  • Gas turbine Mark VI control rack internal communication coordination
  • Steam turbine control and protection system real-time data exchange
  • Combined cycle power plant distributed turbine control systems
  • TMR redundant power generation control cabinets
  • Cross-rack I/O expansion communication for Mark VI systems
  • Power plant control cabinet maintenance, spare replacement and retrofit
  • Oil & gas turbine-driven equipment control systems
  • Critical rotating machinery high-reliability control network interface
GE IS215VCMIH2C VME 6U Bus Master Communication Base Board for Mark VI Speedtronic turbine control system
Product Uses
  • Act as VME bus master to manage communication between CPU and all local I/O boards inside the rack
  • Transmit real-time control commands and collect analog/digital feedback data via three IONet channels
  • Enable reliable data communication between main control racks and remote expansion racks
  • Support TMR synchronization for redundant turbine control and protection systems
  • Provide local serial diagnostic access for commissioning and troubleshooting
  • Identify and manage hardware IDs of all modules and terminal boards within the VME rack
  • Serve as base board for CA / CB coated variants and direct drop-in replacement spare board
  • Support turbine control system overhaul, life extension and spare inventory management
Warranty

We provide a 12-month limited warranty for the GE IS215VCMIH2C board. The warranty covers functional failures caused by manufacturing defects under normal installation and operating conditions. During the warranty period, qualified faulty units are eligible for free repair or replacement. Every board is fully tested and inspected before shipment.

The warranty does NOT cover damage caused by improper installation, overvoltage, short circuit, physical impact, corrosion, unauthorized modification, ESD damage or abnormal industrial misuse. Technical support is available for product consultation, wiring guidance and fault diagnosis.

Frequently Asked Questions (FAQ)
Q1: Which control system is IS215VCMIH2C compatible with?

A: It is designed for the GE Mark VI Speedtronic turbine control system and acts as the rack communication master.

Q2: What does VCMI stand for?

A: VCMI means VME Communication Master Interface, the main communication hub board for Mark VI racks.

Q3: What is the relationship between IS215VCMIH2C, IS215VCMIH2CA and IS215VCMIH2CB?

A: IS215VCMIH2C is the base uncoated board; IS215VCMIH2CA and IS215VCMIH2CB are coated revision variants built from this base platform.

Q4: What ports are available on this board?

A: It is equipped with three 10Base2 IONet Ethernet ports and one RS-232 serial diagnostic port with reset button.

Q5: Does this board support TMR redundant configuration?

A: Yes, it supports both simplex and Triple Modular Redundancy (TMR) architectures for high-reliability turbine control.

Q6: What power supply does this board require?

A: Nominal 28 VDC, operating range 18–32 VDC.

Q7: Is this board the main CPU controller?

A: No. It is a dedicated communication master board responsible for VME bus and IONet network data exchange.

Q8: What is the difference between base H2C and coated CA/CB versions?

A: The base H2C has no conformal coating; CA and CB add conformal coating for dust and moisture protection in industrial cabinets.

Q9: Are the boards tested before shipment?

A: Yes, all units pass complete functional testing and quality inspection before delivery.

Q10: What should I confirm before installing the replacement board?

A: Confirm the full part number, verify rack slot compatibility, check power supply, confirm whether coating version is required, and follow GE Mark VI installation manuals.

Related Products
Product Details
Highlight:

VME 6U Bus Master Board

,

GE VCMIH2C Communication Module

,

IS215VCMIH2C Base Board Parts

Voltage Rating: 12V To 48V DC
Voltage: 120V / 240V
Installation Type: Plug And Play
Packagecontents: 1 X GE Module Part, Installation Guide
Usage: Replacement Parts For GE Modules
Current Rating: Up To 30A
Weight: 250 Grams
Voltagerating: 120V - 240V

Miss. Liliya