IS215VPROH1B Module Parts Stacked Turbine Emergency Protection Assembly in Stock
The GE IS215VPROH1B is a stacked turbine emergency protection assembly designed for the Mark VI Speedtronic turbine control system. As a dedicated VPRO (Turbine Protection) module, it provides independent safety protection and emergency trip functions for gas turbines, steam turbines, and combined cycle power plants. The assembly operates as a standalone protection subsystem, electrically and logically isolated from the main turbine control logic, ensuring reliable emergency shutdown capability for critical rotating machinery.
| Brand | General Electric (GE) |
|---|---|
| Manufacturer | GE Vernova |
| Part Number | IS215VPROH1B |
| Functional Acronym | VPRO (Turbine Protection) |
| Series | Mark VI Speedtronic Turbine Control System |
| Module Type | Stacked Turbine Emergency Protection Assembly |
| Redundancy Support | Simplex and Triple Modular Redundancy (TMR) |
| Input Signals | Magnetic pickup speed signals, thermocouple inputs, 4-20mA analog inputs, discrete trip contact signals |
| Output Signals | Relay trip outputs for turbine shutdown solenoids |
| Communication | IONet Ethernet interface |
| Pulse Input Range | 2 Hz to 20 kHz |
| MPU Input Sensitivity | Minimum 27 mV peak at 2 Hz |
| Power Supply | 125 VDC nominal, operating range 70-140 VDC |
| PCB Protection | Standard conformal coating |
| Operating Temperature | 0 °C ~ +60 °C |
| Storage Temperature | -40 °C ~ +85 °C |
| Humidity | 10-95% non-condensing |
| Diagnostic Indicators | Front-panel LED status indicators (RUN, FAIL, STATUS) |
| Compatible Terminal Boards | TPRO, TREG, TRPG terminal boards |
| Mounting | Standard Mark VI VME rack slot installation |
| Cooling | Natural convection |
| Country of Origin | United States |
- Protection Functions: Emergency Overspeed (EOS), speed difference detection, backup synchronization check, turbine emergency trip, fault interlock protection
- Processing Mode: Independent dedicated protection processor, electrically and logically isolated from main control logic
- Trip Response: Fast deterministic response for safety protection loops
- Signal Isolation: Galvanic isolation between field sensors and internal logic circuits
- Diagnostics: Continuous onboard self-testing and fault indication
- Form Factor: Stacked dual-board VME plug-in assembly
- System Architecture: Independent protection subsystem, decoupled from regular turbine control functions
- Solenoid Drive: Supports up to 3 trip solenoids for turbine shutdown circuits
- System Compatibility: Works with Mark VI gas turbine, steam turbine and combined cycle control cabinets
- Variant Note: IS215VPROH1B is the earlier VPRO assembly; IS215VPROH2B / BC / BD are later upgraded versions
- Gas turbine safety protection and emergency trip systems
- Steam turbine overspeed protection and safety interlock control
- Combined cycle power plant Mark VI control cabinet redundant protection subsystems
- Turbine-driven equipment safety monitoring in oil & gas industry
- Power plant maintenance, spare replacement and system retrofit projects
- High-reliability TMR safety protection cabinets for critical rotating machinery
- Generator protection and emergency shutdown control systems
- Monitor turbine rotational speed via magnetic pickups and trigger emergency overspeed trip
- Detect speed deviation and execute backup synchronization check to prevent unsafe breaker closing
- Process thermocouple temperature signals and analog process parameters for protection interlocks
- Execute hardwired turbine trip logic and output relay commands to trip solenoids and shutoff devices
- Provide independent safety protection, separated from the main turbine control function
- Support simplex and TMR redundant protection architectures for high safety integrity
- Serve as direct drop-in replacement spare assembly for existing Mark VI VPRO racks
- Support turbine control system overhaul, life extension and spare inventory management
We provide a 12-month limited warranty for the GE IS215VPROH1B assembly. The warranty covers functional failures caused by manufacturing defects under normal installation and operating conditions. During the warranty period, qualified faulty units are eligible for free repair or replacement. Every assembly is fully tested and inspected before shipment.
The warranty does NOT cover damage caused by improper installation, overvoltage, short circuit, physical impact, corrosion, unauthorized modification, ESD damage or abnormal industrial misuse. Technical support is available for product consultation, wiring guidance and fault diagnosis.
A: It is designed for the GE Mark VI Speedtronic turbine control system and works as an independent turbine protection subsystem.
A: VPRO is the functional abbreviation for turbine protection assembly, dedicated to overspeed and emergency trip protection.
A: IS215VPROH1B is an earlier stacked dual-board VPRO assembly; IS215VPROH2B / BC / BD are later single-board updated versions with different coating options.
A: Yes, it supports both simplex and Triple Modular Redundancy (TMR) architectures for high safety integrity.
A: Nominal 125 VDC, operating range 70-140 VDC.
A: Magnetic pickup speed signals, thermocouple inputs, 4-20mA analog inputs and discrete trip contact signals.
IS215VPROH1B Turbine Protection Module
,GE Module Parts Emergency Assembly
,Stacked Turbine Protection Assembly
-
IS215VCMIH2CA IS200VCMIH2CAA GE Module Parts VME 6U Bus Master Communication Interface Board in Stock
GE Mark VI VCMI board (IS215VCMIH2CA) offers reliable VME bus master control with TMR redundancy, 3 IONet ports, and conformal coating. UL/CE certified, 1-year warranty, in stock for immediate global export. -
IS215VCMIH2CB GE Module Parts VME Bus Master Communication Interface Board New
GE IS215VCMIH2CB VME Bus Master Communication Interface Board for Mark VI turbine control. Features 32-bit DSP, 3x IONet ports, RS-232 diagnostics, conformal coating, and TMR redundancy support. Reliable, plug-and-play, with 12-month warranty. -
ABB PFSA145 3BSE008843R1 | Power Filter / Transformer for PFSA105 Tension Systems
ABB PFSA145 3BSE008843R1 power filter/transformer for PFSA105 tension systems. Durable, efficient, IEC/UL certified, operates -40~150°C. Original ABB spare part ensures compatibility and reduced downtime. Confirm specs before purchase.